Trunk Line Passives
TLPG2-1H (2, 3, 3E, 3X)H / TDCG2-8 (12, 16)H
- 5 ~ 1218 MHz broad band operation
- All ports with 6KV (combination wave) surge resistance
- 15 A through current rating to support network powered telephony service
- Aluminum alloy 360 housing with chromate conversion coating and powder-coating
- Woven metallic gasket for RFI shielding requirement
- Full weather seal with strand clamp for outdoor applications
- All input/ output connectors are 5/8" - 24NEF female
Insertion Loss (dB max.) | |||||||||
Model Name | port, (MHz) | 5 ~ 15 | 15 ~ 40 | 40 ~ 250 | 250 ~ 550 | 550 ~ 750 | 750 ~ 862 | 862 ~ 1006 | 1006 ~ 1218 |
TLPG2-1H-6K | In - Out | 0.7 | 0.7 | 0.7 | 0.7 | 1.0 | 1.3 | 1.3 | 1.7 |
TLPG2-2H-6K | In - Out | 3.9 | 4.2 | 4.2 | 4.2 | 4.5 | 4.8 | 5.3 | 6.5 |
TLPG2-3H-6K | In - Out (3.7dB) | 4.3 | 4.3 | 4.3 | 4.3 | 4.6 | 5.2 | 5.4 | 6.5 |
TLPG2-3XH-6K | In - Out (7.5dB) | 7.5 | 7.5 | 7.5 | 8.3 | 8.5 | 9.0 | 9.5 | 10.5 |
TLPG2-3EH-6K | In - Out | 7.0 | 6.5 | 6.5 | 7.0 | 7.3 | 7.5 | 8.5 | 9.3 |
Isolation (dB min.) | |||||||||
Model Name | (MHz) | 5 ~ 15 | 15 ~ 40 | 40 ~ 250 | 250 ~ 550 | 550 ~ 750 | 750 ~ 862 | 862 ~ 1006 | 1006 ~ 1218 |
TLPG2-1H-6K | 75 | 60 | 60 | 60 | 60 | 50 | 50 | 43 | |
TLPG2-2H-6K | 18 | 25 | 25 | 21 | 21 | 20 | 18 | 16 | |
TLPG2-3H-6K | 21 | 22 | 22 | 22 | 21 | 20 | 20 | 18 | |
TLPG2-3EH-6K | 18 | 22 | 22 | 22 | 21 | 20 | 20 | 18 | |
TLPG2-3XH-6K | 21 | 22 | 22 | 22 | 21 | 20 | 20 | 18 | |
Return Loss (dB min.) | |||||||||
Model Name | port, (MHz) | 5 ~ 15 | 15 ~ 40 | 40 ~ 250 | 250 ~ 550 | 550 ~ 750 | 750 ~ 862 | 862 ~ 1006 | 1006 ~ 1218 |
TLPG2-1H-6K | In/ Out | 17 | 18 | 18 | 16 | 16 | 16 | 16 | 14 |
TLPG2-2H-6K | In/ Out x 2 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 |
TLPG2-3H-6K | In/ Out x 3 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 |
TLPG2-3EH-6K | In/ Out x 3 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 |
TLPG2-3XH-6K | In/ Out x 3 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 |
General Specifications | |||||||||
Each Leg AC Current Capability | 15 A / 90 VAC | ||||||||
Total AC Powering Capability | 20 A / 90 VAC (TLPG2-1H-6K) ; 15 A / 90 VAC | ||||||||
HUM Modulation | ≧ 70 dB (@ 10A Power Passing) ; ≧ 70 dB (@ 15A Power Passing) |
||||||||
Waterproof Condition | 15 PSI / IP68 | ||||||||
Surge Protection (According to IEC 61000-4-5) | 6 KV (Combination Wave 3KA B3 @2W) | ||||||||
Screening | (According to EN50083-2 ) | Class A | |||||||
Operating Temperature | -40℃ ~ +60℃ | ||||||||
Storage Temperature | -40℃ ~ +60℃ | ||||||||
Impendance | 75 W | ||||||||
Net Weight | 600 g |
Insertion Loss (dB max.) | |||||||||
Model Name | (MHz) | 5 ~ 15 | 15 ~ 40 | 40 ~ 250 | 250 ~ 550 | 550 ~ 750 | 750 ~ 862 | 862 ~ 1006 | 1006 ~ 1218 |
TDCG2-8H-6K | 1.8 | 1.6 | 2.0 | 2.0 | 2.5 | 2.9 | 3.1 | 3.6 | |
TDCG2-12H-6K | 1.2 | 1.2 | 1.5 | 1.8 | 1.8 | 2.2 | 2.4 | 3.0 | |
TDCG2-16H-6K | 1.1 | 1.0 | 1.2 | 1.4 | 1.8 | 2.2 | 2.2 | 2.5 | |
Tap Loss (± 1.5dB) | |||||||||
Model Name | (MHz) | 5 ~ 15 | 15 ~ 40 | 40 ~ 250 | 250 ~ 550 | 550 ~ 750 | 750 ~ 862 | 862 ~ 1006 | 1006 ~ 1218 |
TDCG2-8H-6K | 8.5 | 8.5 | 8.5 | 8.5 | 8.5 | 8.5 | 8.5 | 8.5 ± 2.5 | |
TDCG2-12H-6K | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 ± 2.5 | |
TDCG2-16H-6K | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 ± 2.5 | |
Out - Tap Isolation (dB min.) | |||||||||
Model Name | (MHz) | 5 ~ 15 | 15 ~ 40 | 40 ~ 250 | 250 ~ 550 | 550 ~ 750 | 750 ~ 862 | 862 ~ 1006 | 1006 ~ 1218 |
TDCG2-8H-6K | 18 | 28 | 28 | 25 | 21 | 18 | 18 | 18 | |
TDCG2-12H-6K | 19 | 23 | 25 | 25 | 20 | 18 | 18 | 18 | |
TDCG2-16H-6K | 21 | 25 | 30 | 25 | 20 | 20 | 20 | 18 | |
Return Loss (dB min.) | |||||||||
Model Name | port, (MHz) | 5 ~ 15 | 15 ~ 40 | 40 ~ 250 | 250 ~ 550 | 550 ~ 750 | 750 ~ 862 | 862 ~ 1006 | 1006 ~ 1218 |
TDCG2-8H-6K | In/ Out | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 |
Tap | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 | |
TDCG2-12H-6K | In/ Out | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 |
Tap | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 | |
TDCG2-16H-6K | In/ Out | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 |
Tap | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 14 | |
General Specifications | |||||||||
Each Leg AC Current Capability | 15 A / 90 VAC | ||||||||
Total AC Powering Capability | 15 A / 90 VAC | ||||||||
HUM Modulation | ≧ 70 dB (@ 10A Power Passing) ; ≧ 70 dB (@ 15A Power Passing) |
||||||||
Waterproof Condition | 15 PSI / IP68 | ||||||||
Surge Protection (According to IEC 61000-4-5) | 6 KV (Combination Wave 3KA B3 @2W) | ||||||||
Screening | (According to EN50083-2 ) | Class A | |||||||
Operating Temperature | -40℃ ~ +60℃ | ||||||||
Storage Temperature | -40℃ ~ +60℃ | ||||||||
Impendance | 75 W | ||||||||
Net Weight | 600 g |